Italtecnica PM5 pressure switch 230 V, 16 A, 1–5 bar, 1/4" swivel nut hoofdafbeelding
  • Italtecnica PM5 pressure switch 230 V, 16 A, 1–5 bar, 1/4" swivel nut - detail 1
  • Italtecnica PM5 pressure switch 230 V, 16 A, 1–5 bar, 1/4" swivel nut - detail 2
  • Italtecnica PM5 pressure switch 230 V, 16 A, 1–5 bar, 1/4" swivel nut - detail 3
  • Italtecnica PM5 pressure switch 230 V, 16 A, 1–5 bar, 1/4" swivel nut - detail 4
  • Italtecnica PM5 pressure switch 230 V, 16 A, 1–5 bar, 1/4" swivel nut - detail 5

Italtecnica PM5 pressure switch 230 V, 16 A, 1–5 bar, 1/4" swivel nut

  • Mechanical pressure switch
  • 230 V, max. 16 A
  • Adjustable 1 – 5 bar
  • 1/4" female with swivel nut
  • Italtecnica, Made in Italy
€17.50

(VAT included)

In stock | Brand: ItalTecnica| EAN: 8032738641899

Since 2012
Free shipping · NL from €100 · BE/DE from €200
In stock: ships within 1-2 business days

Description

The Italtecnica PM5 is a mechanical pressure switch for booster sets with a single-phase 230 V pump up to max. 16 A. It starts the pump when the pressure drops and stops it again once the set pressure is reached. The switching pressure is adjustable between 1 and 5 bar. From the factory, the PM5 is set to 1.4 bar on and 2.8 bar off.

The pressure connection is a 1/4" female thread with a swivel nut and gasket. You don’t need to turn the switch itself: you screw the nut onto the 1/4" male thread of, for example, a 5-way connector, and the gasket makes the seal. No PTFE tape is needed. The PM5 is supplied without a cable.

How to set the PM5: 

  • 1. First unplug the pump or switch off the circuit breaker. The switch carries 230 V.
  • 2. Undo the screw on top of the cover and remove the cover. You will see two springs: a large one and a small one.
  • 3. The large spring sets when the pump switches on. Turn the nut on the large spring clockwise (tighter): the pump switches on sooner, at a higher pressure. Anticlockwise (looser): the pump switches on later, at a lower pressure. Note: the large spring also moves the cut-out pressure up or down with it.
  • 4. The small spring sets how much higher the pump switches off. This gap is called the “differential”. Turn the nut on the small spring clockwise: the pump switches off at a higher pressure, so the gap gets bigger. Anticlockwise: the pump switches off sooner, so the gap gets smaller.
  • 5. Turn half a turn to one full turn at a time, refit the cover, switch the power back on and read on the pressure gauge at which pressure the pump starts and stops. Repeat until the values are right.
  • 6. Set the pressure vessel pre-charge 0.2 to 0.3 bar below the cut-in pressure. For example, if the pump starts at 2.0 bar, set the vessel to 1.7–1.8 bar.

A gap of 1 to 1.5 bar between on and off works well for most domestic installations.

Product Details

Voltage
230 Volts
Max. pressure (bar)
5,0 bar
Material
Kunststof

You might also like